aµtoPULSE Software Update 1.6

Explore the new features and improvements in the latest aµtoPULSE release. Download the software to get started.

Note

This What’s New covers aµtoPULSE versions 1.5 and 1.6.

Dynamic Protocol Queue

Added in version 1.5

You can now add a new protocol while another one is running—new profiles are automatically added to the queue. You can also edit profiles already in the queue before they run.

This gives you the flexibility to create and run samples on demand, without needing to plan everything upfront. Multiple users can also share the instrument, queuing their own protocols independently without interrupting runs already in progress. See Running a Protocol for detailed instructions.

Multiple_Protocols_in_Runtime_Status_Page1
Multiple Protocols in Runtime Status Page

Adjust Profile Settings During a Run

Added in version 1.6

You can now adjust Feed Pressure, Retentate Pressure, and Time Multiplier during a run to quickly find suitable settings for each sample without creating multiple profiles. For more information, see Runtime Status.

Adjustable Parameters During Run
Adjustable Parameters During Run

Process Sample Multiple Times

Added in version 1.5

aµtoPULSE now allows you to process samples multiple times across different profiles—ideal for multiple buffer exchanges or processing sample volumes larger than 100 mL. The software automatically updates the final volume from the previous profile, saving setup time and reducing entry errors. For more information, see Creating Profiles.

Selecting_and_Reusing_Sample_Tube1
Selecting and Reusing Sample Tube
New Options for Advanced Setup

Added in version 1.6

aµtoPULSE now supports:

  • Process Samples Using Only the Small Membrane

    Added a Small Membrane Only option to help reduce sample loss due to membrane binding, with a corresponding increase in processing time.

  • Sample Recirculation Before Recovery

    aµtoPULSE now supports Sample Recirculation, allowing fresh sample to flow over the membrane to improve sample recovery.

small_membrane_only_and_sample_recirculation1
Small Membrane Only and Sample Recirculation in Advanced Setup
Minor Software Changes

aµtoPULSE includes several minor changes for better usability:

  • aµtoPULSE now checks additional instrument readiness requirements before starting a run.
  • Improved accuracy for processing low-volume samples in Left Tube.
  • Added support for 2 tube samples to be concentrated into a microtube.
  • Improved volume accuracy of buffer recovery process.
  • Added density mixing calculation for processing multiple fluids with different densities.
  • Added insufficient-volume error detection during buffer exchange, with error logs and total transferred buffer volume in Protocol Result and Summary.
  • Added Chip Priming header column in the CSV Profile template.
  • Improvements on the UI across the software, including:
    • Added real-time push notifications across the software for key protocol statuses: Runtime Stopped, Labware Returned, Protocol Stopped, Protocol Finished.
    • Added Running Protocol Status badge runningprotocol to the Explorer and Editor pages to identify the active running protocol.
    • Added buttons on the Editor page to support protocol queuing: SHOW USED NEST (displays nests used by other protocols); SYNC (applies the edited active profiles to the Runtime Status queue).
    • Additional functions on the Runtime Status page:
      • Running Protocol panel for easier monitoring. It includes Protocol Summary protocolsummary , Return Labware returnlabware , and Close Protocol closeprotocol buttons.
      • Deck panel to display nests currently used by running protocols.
      • Added an Error Detected notification that specifies the issue and the affected protocol.
  • Multiple bug fixes to correct minor issues.